AS/NZS 5033:2021

PV String Calculator

Size PV strings against your inverter's voltage and current limits, with cold-weather Voc correction by temperature coefficient or AS/NZS 5033:2021 Table 4.1. Enter the module datasheet values and the results update as you type.

PV module — datasheet (STC)

Cold-Voc method

Enter coefficients exactly as the datasheet shows them, e.g. −0.25. γ is used for hot-weather Vmp; leave it blank to fall back to β.

Module type

Site temperatures

Use the record low for the site (daytime module temperature can reach ambient at sunrise). 70 °C cell temperature suits most ventilated rooftop arrays; use 75–80 °C for poorly ventilated mounting.

Inverter / MPPT

Allowable string length
Check a string of
modules CHECKS

    String voltage vs inverter window

    0 V

    Derived values

    AS/NZS 5033:2021 Table 4.1 — cold Voc factors
    Lowest expected temperatureVoc correction factor

    Applies to crystalline and multi-crystalline silicon modules where the manufacturer's Voc temperature coefficient is not available. Where the coefficient is available, the coefficient method gives the exact figure and should be preferred.